Those Fucking Morons…

Why on earth people from HP think that the rest of the world is full of idiots and they are the only ones who actually know anything? My first question here is, do they know anything at all?

As I have ranted against them a LONG time on this blog and my old, I am not going to waste my time reinventing the wheel. I can sue them this time and I have evidence. It turns out that the receipt they gave me which says hard disk was replaced is either wrong meaning they did not replace the drive at all, OR it means that they replaced my old drive with a refurbished non resetted hard disk. How do I know this? S.M.A.R.T. tools. The report log of the hard disk is attached…. Read yourself the fields, power on hours and the numerous errors… they have NOT replaced the hard disk…. morons…

smartctl 5.39 2008-05-08 21:56 [i686-pc-linux-gnu] (local build)
Copyright (C) 2002-8 by Bruce Allen, http://smartmontools.sourceforge.net
 
=== START OF INFORMATION SECTION ===
Model Family:     Hitachi Travelstar 5K100 series
Device Model:     HTS541040G9AT00
Serial Number:    MPB2LAX2CXWJLM
Firmware Version: MB2OA60A
User Capacity:    40,007,761,920 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   6
ATA Standard is:  ATA/ATAPI-6 T13 1410D revision 3a
Local Time is:    Mon Nov 10 01:52:17 2008 IST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
 
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
 
General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      ( 248)	Self-test routine in progress...
					80% of test remaining.
Total time to complete Offline
data collection: 		 ( 645) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					No General Purpose Logging support.
Short self-test routine
recommended polling time: 	 (   3) minutes.
Extended self-test routine
recommended polling time: 	 (  30) minutes.
 
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   084   062    Pre-fail  Always       -       0
  2 Throughput_Performance  0x0005   105   100   040    Pre-fail  Offline      -       4565
  3 Spin_Up_Time            0x0007   205   100   033    Pre-fail  Always       -       1
  4 Start_Stop_Count        0x0012   096   096   000    Old_age   Always       -       7403
  5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail  Always       -       1376345
  7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       -       0
  8 Seek_Time_Performance   0x0005   120   100   040    Pre-fail  Offline      -       40
  9 Power_On_Hours          0x0012   086   086   000    Old_age   Always       -       6316
 10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   098   098   000    Old_age   Always       -       4246
191 G-Sense_Error_Rate      0x000a   100   094   000    Old_age   Always       -       1
192 Power-Off_Retract_Count 0x0032   099   099   000    Old_age   Always       -       233
193 Load_Cycle_Count        0x0012   081   081   000    Old_age   Always       -       191669
194 Temperature_Celsius     0x0002   125   098   000    Old_age   Always       -       44 (Lifetime Min/Max 13/56)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       21
197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x000a   200   200   000    Old_age   Always       -       0
 
SMART Error Log Version: 1
ATA Error Count: 15565 (device log contains only the most recent five errors)
	CR = Command Register [HEX]
	FR = Features Register [HEX]
	SC = Sector Count Register [HEX]
	SN = Sector Number Register [HEX]
	CL = Cylinder Low Register [HEX]
	CH = Cylinder High Register [HEX]
	DH = Device/Head Register [HEX]
	DC = Device Command Register [HEX]
	ER = Error register [HEX]
	ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
 
Error 15565 occurred at disk power-on lifetime: 6211 hours (258 days + 19 hours)
  When the command that caused the error occurred, the device was active or idle.
 
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  10 51 00 ff ff ff ef  Error: IDNF at LBA = 0x0fffffff = 268435455
 
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  ca 00 01 ff ff ff ef 00      00:00:08.800  WRITE DMA
  ca 00 01 7d c5 fa e0 00      00:00:08.800  WRITE DMA
  c8 00 01 00 00 00 e0 00      00:00:08.800  READ DMA
  f8 00 00 be 4d a8 e0 00      00:00:07.400  READ NATIVE MAX ADDRESS
  c5 00 10 af 4d a8 e4 00      00:00:07.300  WRITE MULTIPLE
 
Error 15564 occurred at disk power-on lifetime: 6211 hours (258 days + 19 hours)
  When the command that caused the error occurred, the device was active or idle.
 
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 3a 0a 22 b8 f2  Error: UNC at LBA = 0x02b8220a = 45621770
 
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  40 03 3f 05 22 b8 f2 00      00:12:26.200  READ VERIFY SECTOR(S)
  40 03 3f c6 21 b8 f2 00      00:12:26.200  READ VERIFY SECTOR(S)
  40 03 3f 87 21 b8 f2 00      00:12:26.200  READ VERIFY SECTOR(S)
  40 03 3f 48 21 b8 f2 00      00:12:26.200  READ VERIFY SECTOR(S)
  40 03 3f 09 21 b8 f2 00      00:12:26.200  READ VERIFY SECTOR(S)
 
Error 15563 occurred at disk power-on lifetime: 6211 hours (258 days + 19 hours)
  When the command that caused the error occurred, the device was active or idle.
 
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 19 5f a0 6a f1  Error: UNC at LBA = 0x016aa05f = 23765087
 
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  40 03 3f 39 a0 6a f1 00      00:06:27.500  READ VERIFY SECTOR(S)
  40 03 3f fa 9f 6a f1 00      00:06:27.500  READ VERIFY SECTOR(S)
  40 03 3f bb 9f 6a f1 00      00:06:27.500  READ VERIFY SECTOR(S)
  40 03 3f 7c 9f 6a f1 00      00:06:27.500  READ VERIFY SECTOR(S)
  40 03 3f 3d 9f 6a f1 00      00:06:27.500  READ VERIFY SECTOR(S)
 
Error 15562 occurred at disk power-on lifetime: 6211 hours (258 days + 19 hours)
  When the command that caused the error occurred, the device was active or idle.
 
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 12 9d f1 66 f1  Error: UNC at LBA = 0x0166f19d = 23523741
 
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  40 03 3f 70 f1 66 f1 00      00:06:18.300  READ VERIFY SECTOR(S)
  40 03 3f 31 f1 66 f1 00      00:06:18.300  READ VERIFY SECTOR(S)
  40 03 3f f2 f0 66 f1 00      00:06:18.300  READ VERIFY SECTOR(S)
  40 03 3f b3 f0 66 f1 00      00:06:18.300  READ VERIFY SECTOR(S)
  40 03 3f 74 f0 66 f1 00      00:06:18.300  READ VERIFY SECTOR(S)
 
Error 15561 occurred at disk power-on lifetime: 6210 hours (258 days + 18 hours)
  When the command that caused the error occurred, the device was active or idle.
 
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 36 ef 1a b0 f0  Error: UNC at LBA = 0x00b01aef = 11541231
 
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  40 03 3f e6 1a b0 f0 00      00:03:15.300  READ VERIFY SECTOR(S)
  40 03 3f a7 1a b0 f0 00      00:03:15.300  READ VERIFY SECTOR(S)
  40 03 3f 68 1a b0 f0 00      00:03:15.300  READ VERIFY SECTOR(S)
  40 03 3f 29 1a b0 f0 00      00:03:15.300  READ VERIFY SECTOR(S)
  40 03 3f ea 19 b0 f0 00      00:03:15.300  READ VERIFY SECTOR(S)
 
SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%      6214         -
# 2  Short offline       Completed without error       00%      6214         -
# 3  Short offline       Completed without error       00%      6213         -
# 4  Short offline       Completed without error       00%      6213         -
# 5  Short offline       Aborted by host               90%      2598         -
# 6  Short offline       Aborted by host               90%      2598         -
# 7  Short offline       Completed without error       00%         4         -
# 8  Short offline       Completed without error       00%         3         -
# 9  Short offline       Completed without error       00%         2         -
#10  Short offline       Completed without error       00%         2         -
#11  Short offline       Completed without error       00%         1         -
#12  Short offline       Completed without error       00%         0         -
#13  Short offline       Completed without error       00%         0         -
 
Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

One more thing which proves my theory… well, not prove it, but it is a symptom, the average loads on staring firefox are like 5.something to even, the worst, 11.6 or so… They royally suck and like screwing their customers… I HATE THEM… Here I was shutting down the laptop for my exams… and now it looks it will spend another month… probably my entire holiday in the service station. Those SoBs will do nothing cause they are SoBs… I am tired of this and I need to study now… seeya all if I can get a new computer… someone gift me a computer please… an assembled desktop is fine too but I won’t mind a macPro….

Tags: , ,

This entry was posted on Monday, November 10th, 2008 at 1:57 am and is filed under HP SUCKS. You can follow any responses to this entry through the RSS 2.0 feed. You can leave a response, or trackback from your own site.

2 Responses to “Those Fucking Morons…”

vedang November 21st, 2008 at 4:53 pm

LOL!
You go right ahead and sue the shit out of them. Go to their office, meet the manager, show him the report and ask him what _he_ thinks you should do. Gently suggest that you may be appeased if they give you a new machine with atleast 4 gb RAM, 2 gb graphics card, 2.4 GHz core 2 duo, 1 TB hdd. The whole works! :D :D

Aditya November 21st, 2008 at 5:11 pm

If only it were possible, I would have done it a LONG time ago. Been right up till the MD of HP India. They are worse than anything I have ever come up against. I am NOT buying an HP computer again.

Leave a Reply